R1 Heat Shrink repair Sleeve
Features: |
Semi-rigid out layer, adhesive lined,moisture-proof; |
|
Emergency cable repair and sealing system; |
Abrasion and corrosion resistant; |
|
Halogen free; |
Steel channel enables permanent closure system; |
|
RoHS compliant ; |
Quickly fitted in breakage,insulating and air-tight repair. |
|
|
Typical application: |
Specifically designed to quickly repair damaged cable jacketing, providing sealing, insulation and protection of odd-shaped electrical objects where tubing insulation . |
Cross reference: |
Raychem/ Tyco : CRSM . |
Dimensions: |
Reference |
As supplied |
After recovered |
Standard length |
UPM R1 |
(mm) |
(mm) |
m |
R1-36/10 |
36 |
10 |
1 |
R1-50/15 |
50 |
15 |
1 |
R1-60/18 |
60 |
18 |
1 |
R1-70/22 |
70 |
22 |
1 |
R1-80/25 |
80 |
25 |
1 |
R1-100/30 |
100 |
30 |
1 |
R1-135/38 |
135 |
38 |
1 |
R1-164/42 |
164 |
42 |
1 |
R1-185/55 |
185 |
55 |
1 |
R1-200/60 |
200 |
60 |
1 |
R1-220/65 |
220 |
65 |
1 |
Technical data:
Property |
Test method |
Values |
Physical |
Tensile strength |
ASTM D2671 |
≥14 MPa |
|
Breakdown elongation |
ASTM D2671 |
≥ 350% |
Aging (150℃ /168hrs) |
Tensile strength |
ASTM D2671 |
≥12 MPa |
Breakdown elongation |
ASTM D2671 |
≥300% |
|
Density |
ASTM D792 |
1.1~1.2 |
|
Low temperature flexibility(-25 ℃/4hrs) |
ASTM D2671 |
No cracking |
|
Hardness (Shore D) |
ASTM D2240 |
40~50 HD |
|
Heat shock (200 ℃/4hrs) |
ASTM D2671 |
No cracking ,no flow |
|
Water absorption |
ASTM D570 |
≤0.5% |
Electrical |
Volume resistivity |
ASTM D257 |
≥1013 Ω.cm |
|
Dielectric strength |
ASTM D2671 |
15 KV/mm |
|
Dielectric constant |
IEC 250 |
≤ 5.0 |
Chemical |
Fungus resistance |
ASTM G21 |
No growth |